Resumo

JUSTIFICATIVA E OBJETIVOS: A cetamina S(+) é importante na modulação da dor em pacientes cirúrgicos. Este trabalho teve por objetivo avaliar a relação entre os níveis de sedação produzidos por baixas doses de cetamina S(+), bem como as variáveis do EEG: BIS, SEF 95%, pEMG, taxa de supressão e presença de surto-supressão. MÉTODO: Trinta pacientes, de ambos os sexos, faixa etária entre 25 e 50 anos, foram distribuídos aleatoriamente em três grupos. O grupo G1 (10) recebeu cetamina S(+) - 0,050 mg.kg-1; o grupo G2 (10), cetamina S(+) - 0,125 mg.kg-1 e o grupo G3(10), cetamina S(+) - 0,250 mg.kg-1; em todos os grupos, a cetamina S(+) foi administrada por via venosa. Todos os pacientes receberam 0,08 mg.kg-1 de midazolam por via venosa 10 minutos antes da administração de cetamina S(+). Em cada grupo, avaliaram-se dois momentos: M1, antes da administração da cetamina S(+); e M2, após a administração da cetamina S(+). Nos três grupos, foram avaliados os níveis de sedação e as variáveis do EEG: BIS, SEF 95%, pEMG, taxa de supressão e presença de surto-supressão, antes e após a injeção de cetamina S(+). Utilizou-se ANOVA para medidas repetidas e valor de p ajustado para comparações múltiplas pelo teste de Tukey. RESULTADOS: Houve diminuição nos escores da escala de alerta sedação nos três grupos nos momentos M2. As variáveis do EEG mostraram variação significante nos três grupos, comparando-se os momentos M1 e M2 tanto na pEMG como no BIS (p < 0,05). CONCLUSÕES: Os níveis de sedação correlacionam-se, de maneira significativa, com o aumento da dose de cetamina S(+). Entretanto, os valores elevados do BIS podem ter refletido aumento da pEMG induzida pela cetamina S(+).

Palavras-chave

ANALGESICOS, MONITORAÇÃO, SEDACAO, TÉCNICAS DE MEDIÇÃO

Abstract

BACKGROUND AND OBJECTIVES: Ketamine S(+) is important in pain modulation in surgical patients. The objective of the present study was to evaluate the relationship between the levels of sedation produced by low doses of ketamine S(+), as well as encephalographic variables: BIS, SEF 95%, pEMG, suppression rate, and presence of burst-suppression. METHODS: Thirty patients of both sexes, aged 25-50 years, were randomized into three groups. Group G1 (10) received intravenous ketamine S(+) 0.050 mg,kg-1; group G2 (10) intravenous ketamine S(+) 0.125 mg.kg-1; and group G3 (10) intravenous ketamine S(+) 0.250 mg.kg-1. All patients received 0.08 mg.kg-1 of intravenous midazolam 10 minutes before administration of ketamine S(+). In each group, two moments were evaluated: M1, before ketamine S(+) administration; and M2, after ketamine S(+) administration. Sedation levels and encephalographic variables: BIS, SEF 95%, pEMG, suppression rate, and the presence of burst-suppression were evaluated in all patients before and after ketamine S(+) administration. ANOVA was used for repeated measurements and the p-value was adjusted for multiple comparisons by Tukey's test. RESULTS: A decrease in alertness-sedation scale scores was observed in all three groups in moment M2. Electroencephalographic variables showed significant variation in all three groups when moments M1 and M2 were compared, both in pEMG and BIS (p < 0.05). CONCLUSIONS: Sedation levels showed significant correlation with the increase in ketamine S(+) dosage. However, increased BIS levels may have reflected increased pEMG induced by ketamine S(+).

Keywords

Ketamine, Deep Sedation, Conscious Sedation, Electroencephalography

References

Hiroka K. Special cases: ketamine, nitrous oxide and xenon. Best Pract Res Clin Anaesthesiol. 2006;20:69-79.

De Koch M, Lavand'Homme P, Waterloos H. "Balanced analgesia" in the perioperative period: is there a place for ketamine?. Pain. 2001;92:373-380.

Patel PM, Drummond JC. Cerebral Physiology and the Effects of Anesthetics and Techniques. Miller's Anesthesia. 2005:813-857.

Cavalcante SL, Nunes RR. Avaliação dos parâmetros derivados do eletroencefalograma durante administração de diferentes concentrações de óxido nitroso. Rev Bras Anestesiol. 2003;53:1-8.

Johansen JW. Update on bispectral index monitoring. Best Pract Res Clin Anaesthesiol. 2006;20:81-99.

Kubota T, Hirota K, Yoshida H. Effects of sedatives on noradrenaline release from the medial prefrontal cortex in rats. Psycopharmacology (Berl). 1999;146:335-338.

Hirota K, Kubota T, Ishihara H. The effects of nitrous oxide and ketamine on the bispectral index and 95% spectral edge frequency during propofol-fentanyl anaesthesia. Eur J Anaesthesiol. 1999;16:779-783.

Brunton LL, Parker KL. Goodman & Gilman's: Manual of Pharmacology and Therapeutics. 2008:231-232.

5dd6c8180e8825c74413f286 rba Articles
Links & Downloads

Braz J Anesthesiol

Share this page
Page Sections