Sistemas respiratórios com absorção de CO2, circulares, valvulares: comparação do comportamento térmico entre sistema coaxial e convencional com diferentes fluxos de gás fresco
Anesthesia breathing systems with CO2 absorption, circle valve circuit: comparison of thermal behavior of coaxial system and conventional system with different fresh gas flows
Marcelo Luís Abramides Torres; Eduardo Tsuyoshi Yamaguchi; Ubirajara Sabbag Fonseca
Resumo
Palavras-chave
Abstract
Keywords
References
Clark RE, Orkin LR, Rovenstine EA. Body temperature studies in anesthetized man: effect of environmental temperature, humidity and anesthesia system. JAMA. 1954;154:311-319.
Rashad K, Wilson k, Hurt HH. Effect of humidification of anesthetic gases on static compliance. Anesth Analg. 1967;46:127-133.
Chalon J, Loew DA, Malebranche J. Effects of dry anesthetic gases on tracheobronchial ciliated epithelium. Anesthesiology. 1972;37:338-343.
Noguchi H, Takumi Y, Aochi O. A study of humidification in tracheostomized dogs. Br J Anaesth. 1973;45:844-848.
Marfatia S, Donahoe PK, Hendren WH. Effect of dry and humidified gases on the respiratory epithelium in rabbits. J Pediatr Surg. 1975;10:583-592.
Tsuda T, Nogushi H, Takumi Y. Optimum humidification of air administered to a tracheostomy in dogs: Scanning electron microscopy and surfactant studies. Br J Anaesth. 1977;49:965-977.
Ferrus l, Guenard h, Vardon G. Respiratory water loss. Respir Physiol. 1980;39:367-381.
Shelly MP, Lloyd GM, Park GR. A review of the mechanisms and methods of humidification of inspired gases. Intensive Care Med. 1988;14:1-9.
Shelly MP. Inspired gas conditioning. Respir Care. 1992;37:1070-1080.
Weeks DB, Broman KE. A method of quantitating humidity in the anesthesia circuit by temperature control: semiclosed circle. Anesth Analg. 1970;49:292-296.
Chalon J, Kao ZL, Dolorico VN. Humidity output of the circle absorber system. Anesthesiology. 1973;38:458-465.
Kleemann PP. Humidity of anaesthetic gases with respect to low flow anaesthesia. Anaesth Intensive Care. 1994;22:396-408.
Bengtson JP, Bengtson A, Stenqvist O. The circle system as a humidifier. Br J Anaesth. 1989;63:453-457.
Torres MLA, Carvalho JCA, Bello CN. Sistemas respiratórios valvulares com absorção de CO2: capacidade de aquecimento e umidificação dos gases inalados em três tipos de montagens utilizadas em aparelhos de anestesia no Brasil. Rev Bras Anestesiol. 1997;47:89-100.
Flynn PJ, Morris LE. Inspired humidity in anaesthesia breathing circuits: comparison and examination of effect of Revell circulator. Can Anaesth Soc J. 1984;31:659-663.
Chalon J, Markham JP, Ali MM. The pall ultipor breathing circuit filter: an efficient heat and moisture exchanger. Anesth Analg. 1984;63:566-570.
Bickler PE, Sessler DI. Efficiency of airway heat and exchangers in anesthetized humans. Anesth Analg. 1990;71:415-418.
Hedley RM, Allt-Graham J. Heat and moisture exchangers and breathing filters. Br J Anaesth. 1994;73:227-236.
Rayburn RL, Watson RL. Humidity in children and adults using the controlled partial rebreathing anesthesia method. Anesthesiology. 1980;52:291-295.