Comparação entre a medida contínua do débito cardíaco e por termodiluição em bolus durante a revascularização miocárdica sem circulação extracorpórea
Continuous and bolus thermodilution cardiac output measurement during off-pump coronary artery bypass surgery
Sílvia M. Kim; Sílvia D. S. Oliveira; Ubirajara S. Fonseca; Luiz Marcelo Sá Malbouisson; José Otávio Costa Auler Júnior; Maria José Carvalho Carmona
Resumo
Palavras-chave
Abstract
Keywords
Referências
Torracca L, Schreuder JJ, Quarti A. Acute effects of beating heart coronary surgery on left ventricular performance. Ann Thorac Surg. 2002;74:S1348-1352.
Couture P, Denault A, Limoges P. Mechanisms of hemodynamic changes during off-pump coronary artery bypass surgery. Can J Anaesth. 2002;49:835-849.
Do QB, Goyer C, Chavanon O. Hemodynamic changes during off-pump CABG surgery. Eur J Cardiothorac Surg. 2002;21:385-390.
D'Ancona G, Karamanoukian H, Lima R. Hemodynamic effects of elevation and stabilization of the heart during off-pump coronary surgery. J Card Surg. 2000;15:385-391.
Watters MP, Ascione R, Ryder IG. Haemodynamic changes during beating heart coronary surgery with the 'Bristol Technique'. Eur J Cardiothorac Surg. 2001;19:34-40.
Nierich AP, Diephuis J, Jansen EW. Heart displacement during off-pump CABG: how well is it tolerated?. Ann Thorac Surg. 2000;70:466-472.
Heames RM, Gill RS, Ohri SK. Off-pump coronary artery surgery. Anaesthesia. 2002;57:676-685.
Singh A, Juneja R, Mehta Y. Comparison of continuous, stat, and intermittent cardiac output measurements in patients undergoing minimally invasive direct coronary artery bypass surgery. J Cardiothorac Vasc Anesth. 2002;16:186-190.
Zollner C, Goetz AE, Weis M. Continuous cardiac output measurements do not agree with conventional bolus thermodilution cardiac output determination. Can J Anaesth. 2001;48:1143-1147.
Higgins TL, Estafanous FG, Loop FD. Stratification of morbidity and mortality outcome by preoperative risk factors in coronary artery bypass patients: A clinical severity score. JAMA. 1992;267:2344-2348.
Stamou SC, Corso PJ. Coronary revascularization without cardiopulmonary bypass in high-risk patients: a route to the future. Ann Thorac Surg. 2001;71:1056-1061.
Cleveland Jr JC, Shroyer AL, Chen AY. Off-pump coronary artery bypass grafting decreases risk-adjusted mortality and morbidity. Ann Thorac Surg. 2001;72:1282-1288.
Bernardes CES, Messias ERR, Carmona MJC. Considerações anestésico-cirúrgicas sobre a revascularização do miocárdio através de minitoracotomia. Rev Bras Anestesiol. 1999;49:196-200.
Jansen EW, Borst C, Lahpor JR. Coronary artery bypass grafting without cardiopulmonary bypass using the octopus method: results in the first one hundred patients. J Thorac Cardiovasc Surg. 1998;116:60-67.
Poli de Figueiredo LF, Malbouisson LM, Varicoda EY. Thermal filament continuous thermodilution cardiac output delayed response limits its value during acute hemodynamic instability. J Trauma. 1999;47:288-293.
Lazor MA, Pierce ET, Stanley GD. Evaluation of the accuracy and response time of STAT-mode continuous cardiac output. J Cardiothorac Vasc Anesth. 1997;11:432-436.