Brazilian Journal of Anesthesiology
https://app.periodikos.com.br/journal/rba/article/doi/10.1590/S0034-70942004000100008
Brazilian Journal of Anesthesiology
Scientific Article

Efeitos observados com diferentes doses de morfina subaracnóidea em ratos

 Effects of different spinal morphine doses in rats

Neuzimar de Souza Freire Silva; Rioko Kimiko Sakata; Adriana Machado Issy

Downloads: 0
Views: 961

Resumo

JUSTIFICATIVA E OBJETIVOS: A morfina por via espinhal promove bom efeito analgésico, mas não é isenta de efeito colateral. O objetivo deste estudo foi investigar os efeitos observados com diferentes doses de morfina por via subaracnóidea. MÉTODO: Foram estudados cinco grupos de sete ratos, 24 horas após colocação de cateter subaracnóideo via cisterna magna sob anestesia com cetamina e xilazina por via muscular. O G1 recebeu 10 µl de solução fisiológica; os grupos G2, G3, G4, e G5 receberam respectivamente 0,1; 0,3; 0,5 e 1 µg de morfina em 10 µl de solução fisiológica. Os animais foram submetidos ao teste de imersão da cauda em água quente no M0 (antes da injeção), e M15, M30, M60, M120 e M180 minutos após injeção. RESULTADOS: Foi observada analgesia nos grupos que receberam morfina, em diversos momentos, quando comparados com o grupo controle e com o tempo antes da injeção de morfina. No G1 houve fraqueza das patas em 4 animais. Agitação ocorreu em M15 no G2 e em M15 e M30 no G3. Tremor mandibular foi observado em M5, M15, M30 e M60 no G2; no G3 foi observado em M5 e M15; no G4, em M5 e no G5, em M5. Prurido foi observado em M5, M15, M30 e M60 no G2; em M5, M15, M30, M60 e M120 no G3; em M5, M15, M30, M60, e M120 no G4; em M5, M15, M30, M60, e M120 no G5. Ausência de diurese ocorreu em M60 no G2; no M15, M30, M60 e M120 no G3; no M60 e M120 no G4; e no M30 e M60 no G5. Sedação ocorreu em M15, M30 e M60 nos grupos 2, 3 e 4; e em M15, M30, M60 e M120 no G5. Alteração respiratória foi observada em M15, M30, M60 no G2; em M15, M30 e M60 no G3; em M15 e M30 nos grupos 4 e 5. CONCLUSÕES: Neste estudo, todas as doses de morfina subaracnóideas administradas provocaram efeitos colaterais; e doses menores que 1 µg promoveram analgesia de curta duração.

Palavras-chave

ANALGÉSICOS, Opióides, ANIMAL, TÉCNICAS ANESTÉSICAS, Regional

Abstract

BACKGROUND AND OBJECTIVES: Spinal morphine promotes adequate pain relief, but is not free from side effects. This study aimed at investigating the effects of different spinal morphine doses.
METHODS: Five groups of seven rats were studied, 24 h after spinal catheter insertion via cisterna magna under anesthesia with muscular ketamine and xylazine. G1 received 10 µl saline solution; groups G2, G3, G4 and G5 received respectively 0.1; 0.3; 0.5 and 1 µg morphine in 10 µl saline solution. Animals were submitted to tail immersion test in hot water at M0 (prior to injection), and M15, M30, M60, M120 and M180 minutes after the injection.
RESULTS: Analgesic effects were observed in groups receiving morphine, in different times, as compared to control and to time before morphine injection. In G1 there was paws weakness in 4 animals. Agitation was observed at M15 in G2 and at M15 and M30 in G3. Mandible tremors were observed at moments M5, M15, M30 and M60 in G2; at M5 and M15 in G3, in M5 in G4, and in M5 in G5. Pruritus was observed at M5, M15, M30 and M60 in G2; at M5, M15, M30, M60 and M120 in G3; at M5, M15, M30, M60, and M120 in G4; and at M5, M15, M30, M60 and M120 in G5. Absence of diuresis was observed at M60 in G2; at M15, M30, M60 and M120 in G3; at M30 and M120 in G4, and at M30, and M60 in G5. Sedation was observed at M15, M30 and M60 in groups 2, 3 and 4; and at M15, M30, M60 and M120 in G5. Respiratory changes were observed at M15, M30 and M60 in G2; at M15, M30 and M60 in G3; at M15 and M30 in groups 4 and 5.
CONCLUSIONS: In this study all morphine doses below 1 µg have promoted short duration analgesia; all spinal morphine doses have produced side effects.

Keywords

ANALGESICS, Opioids: morphine; ANIMAL: rat, ANESTHETIC TECHNIQUES, Regional: spinal block

Referências

Snyder SH, Pert CB, Pasternak GW. The opiate receptor. Ann Intern Med. 1974;81:534-540.

Yaksh TL, Rudy TA. Studies on direct spinal action of narcotic in the production of analgesia in the rat. J Pharmacol Exp Ther. 1977;202:411-428.

Wang JK, Nauss LA, Thomas JE. Pain relief by intrathecally applied morphine in man. Anesthesiology. 1979;50:149-151.

Yaksh L, Rudy TA. Chronic catheterization of the spinal subarachnoid space. Physiol Behav. 1976;17:1031-1036.

Van den Hoogen RGW, Colpaert FC. Long term catheterization of the lumbar epidural space in rats. Pharmacol Biochem Behav. 1981;15:515-516.

Dib B. Intrathecal chronic catheterization in the rat. Pharmacol Biochem Behav. 1984;20:45-48.

Immelman L, Roth S, Sabourin MA. Analgesia and serum concentrations of extradural, subdural and intraperitoneal fentanyl in a rat model. Can J Anaesth. 1990;37:63-68.

Nishiyama T. A rat model of chronic lumbar epidural catheterization. Can J Anaesth. 1998;45:907-912.

Matos FF, Rollema H, Taiwo Y. Relationship between analgesia and extracelular morphine in brain and spinal cord in awake rats. Brain Research. 1995;693:187-195.

Bahar M, Rosen M, Vickers MD. Chronic cannulation of the intradural or extradural space in the rat. Br J Anaesth. 1984;56:405-410.

Janssen PAJ, Niemeregeers CJE, Dony JG. The inhibitory effect of fentanyl and other dinorphine-like analgesics on the warm water induced tail withdrawal reflex in rats. Arzneimittel-Forsch. 1963;13:502-507.

Porro CA, Carli G. Immobilization and restraint effects on pain reactions in animals. Pain. 1988;32:289-307.

Gustafsson LL, Post C, Edvardsen B. Distribution of morphine and meperidine after intrathecal administration in rat and mouse. Anesthesiology. 1985;63:484-489.

Jaffe JH, Martin WR. Opioid Analgesics and Antagonists. Goodman & Gilman's: The Pharmacological Basis of Therapeutics. 1990:485-521.

5dd7f6d90e88258b1813f286 rba Articles
Links & Downloads

Braz J Anesthesiol

Share this page
Page Sections