Brazilian Journal of Anesthesiology
https://app.periodikos.com.br/journal/rba/article/doi/10.1016/j.bjane.2026.844847
Brazilian Journal of Anesthesiology
Original Investigation

Cervical spine motion during tracheal intubation with videolaryngoscopy versus Macintosh laryngoscopy in adults undergoing cervical spine surgery: a randomized controlled trial

Movimentação da coluna cervical durante a intubação traqueal com videolaringoscopia versus laringoscopia de Macintosh em adultos submetidos à cirurgia de coluna cervical: um ensaio clínico randomizado

Hieu Trung Doan, Thang Toan Nguyen, Anh Thi Hong Nguyen, Du Gia Hoang

Downloads: 2
Views: 6

Abstract

Background

Excessive cervical spine motion during tracheal intubation may increase neurological risk in individuals with cervical spine pathology. Videolaryngoscopy may reduce cervical motion compared with Macintosh direct laryngoscopy, but any biomechanical reduction should be distinguished from neurological protection.

Methods

Adults scheduled for elective cervical spine surgery were randomized 1:1 to intubation with a ClearVue videolaryngoscope (group V) or a Macintosh laryngoscope (group M) under manual in-line stabilization. Lateral fluoroscopy was acquired immediately before laryngoscopy (G0, neutral position) and at best glottic view (G1). The prespecified primary endpoint was directly measured cumulative C0‒C5 cervical motion. Cervical spine motion (ΔG) was also calculated at C0‒C1, C1‒C2, C2‒C3, C3‒C4 and C4‒C5. ΔG was expressed in degrees (°).

Results

Fifty-six patients were randomized and analyzed (28 per group). Mean (SD) ΔG at C0‒C5 was 19.71 (4.75) in group V and 26.32 (8.46) in group M (mean difference [M‒V], 6.61; 95% CI 2.91‒10.31; p < 0.001). At C0‒C1, ΔG was 2.68 (2.53) vs. 4.68 (2.42) (difference = 2.00; 95% CI 0.67‒3.33; p = 0.004). First-attempt success was 89.3% (25/28) vs. 78.6% (22/28) (p = 0.47). Among patients intubated successfully on the first attempt, intubation time was shorter in group V (21.75 ± 3.64 s) than group M (31.71 ± 21.25 s).

Conclusion

ClearVue videolaryngoscopy reduced fluoroscopically measured upper cervical and directly measured cumulative C0‒C5 motion compared with Macintosh direct laryngoscopy. These findings should be interpreted as biomechanical surrogate outcomes, not as evidence of neurological protection.

Keywords

Airway management; Cervical vertebrae; Fluoroscopy; Randomized con-trolled trial; Tracheal intubation; Videolaryngoscopes

Resumo

Introdução

A movimentação excessiva da coluna cervical durante a intubação traqueal pode aumentar o risco neurológico em indivíduos com patologia da coluna cervical. A videolaringoscopia pode reduzir a movimentação cervical em comparação com a laringoscopia direta de Macintosh, mas qualquer redução biomecânica deve ser distinguida da proteção neurológica.

Métodos

Adultos agendados para cirurgia eletiva da coluna cervical foram randomizados na proporção de 1:1 para intubação com videolaringoscópio ClearVue (grupo V) ou laringoscópio de Macintosh (grupo M) sob estabilização manual em linha. A fluoroscopia lateral foi adquirida imediatamente antes da laringoscopia (G0, posição neutra) e na melhor visualização glótica (G1). O desfecho primário pré-especificado foi a movimentação cervical cumulativa de C0 a C5 medida diretamente. A movimentação da coluna cervical (ΔG) também foi calculada em C0–C1, C1–C2, C2–C3, C3–C4 e C4–C5. A ΔG foi expressa em graus (°).

Resultados

Cinquenta e seis pacientes foram randomizados e analisados (28 por grupo). A ΔG média (DP) em C0–C5 foi de 19,71 (4,75) no grupo V e 26,32 (8,46) no grupo M (diferença média [M–V], 6,61; IC 95% 2,91–10,31; p < 0,001). Em C0–C1, a ΔG foi de 2,68 (2,53) vs. 4,68 (2,42) (diferença = 2,00; IC 95% 0,67–3,33; p = 0,004). O sucesso na primeira tentativa foi de 89,3% (25/28) vs. 78,6% (22/28) (p = 0,47). Entre os pacientes intubados com sucesso na primeira tentativa, o tempo de intubação foi menor no grupo V (21,75 ± 3,64 s) do que no grupo M (31,71 ± 21,25 s).

Conclusão

A videolaringoscopia ClearVue reduziu a movimentação da coluna cervical superior medida por fluoroscopia e a movimentação cumulativa de C0 a C5 medida diretamente em comparação com a laringoscopia direta de Macintosh. Esses achados devem ser interpretados como desfechos substitutos biomecânicos, não como evidência de proteção neurológica.

Palavras-chave

Manejo de vias aéreas; Vértebras cervicais; Fluoroscopia; Ensaio clínico randomizado; Intubação traqueal; Videolaringoscópios

References

1. Crosby ET, Warltier DC. Airway management in adults after cervical spine trauma. Anesthesiology. 2006;104:1293−318.

2. White 3rd AA, Johnson RM, Panjabi MM, Southwick WO. Biomechanical analysis of clinical stability in the cervical spine. Clin Orthop Relat Res. 1975(109):85−96.

3. Sawin PD, Todd MM, Traynelis VC, et al. Cervical spine motion with direct laryngoscopy and orotracheal intubation: an in vivo cinefluoroscopic study of subjects without cervical abnormality. Anesthesiology. 1996;85:26−36.

4. Brimacombe J, Keller C, Kunzel KH, Gaber O, Boehler M, Puhringer F. Cervical spine motion during airway management: a cinefluoroscopic study of the posteriorly destabilized third cervical vertebrae in human cadavers. Anesth Analg. 2000;91:1274−8.

5. Wong DM, Prabhu A, Chakraborty S, Tan G, Massicotte EM, Cooper R. Cervical spine motion during flexible bronchoscopy compared with the Lo-Pro GlideScope®. Br J Anaesth. 2009;102:424−30.

6. Robitaille A, Williams SR, Tremblay MH, Guilbert F, Theriault M, Drolet P. Cervical spine motion during tracheal intubation with manual in-line stabilization: direct laryngoscopy versus GlideScope® videolaryngoscopy. Anesth Analg. 2008;106:935−41.

7. Hindman BJ, Santoni BG, Puttlitz CM, From RP, Todd MM. Intubation biomechanics: laryngoscope force and cervical spine motion during intubation with Macintosh and Airtraq laryngoscopes. Anesthesiology. 2014;121:260−71.

8. Turkstra TP, Pelz DM, Jones PM. Cervical spine motion: a fluoroscopic comparison of the AirTraq laryngoscope versus the Macintosh laryngoscope. Anesthesiology. 2009;111:97−101.

9. Kleine-Brueggeney M, Greif R, Schoettker P, Savoldelli GL, Nabecker S, Theiler LG. Evaluation of six videolaryngoscopes in 720 patients with a simulated difficult airway: a multicentre randomized controlled trial. Br J Anaesth. 2016;116:670−9.

10. Kaur K, Raja R, Kumar P, Singh R, Vashishth S, Singh HD, et al. A comparative study to evaluate the cervical spine movements during laryngoscopy using Macintosh and Airtraq laryngoscopes. J Anaesthesiol Clin Pharmacol. 2024;40:101−7.

11. Jo WY, Choi JH, Kim J, et al. Cervical spine motion during videolaryngoscopic intubation using a Macintosh-style blade with and without the anterior piece of a cervical collar: a randomized controlled trial. Can J Anaesth. 2025;72:142−51.

12. Akbar SHM, Ooi JSM. Comparison between C-MAC video-laryngoscope and Macintosh direct laryngoscope during cervical spine immobilization. Middle East J Anaesthesiol. 2015;23:43−50.

13. Rudolph C, Schneider JP, Wallenborn J, Schaffranietz L. Movement of the upper cervical spine during laryngoscopy: a comparison of the Bonfils intubation fibrescope and the Macintosh laryngoscope. Anaesthesia. 2005;60:668−72.

14. Stier GR, Gabriel CL, Cole DJ. Neurosurgical diseases and trauma of the spine and spinal cord: anesthetic considerations. In: Cottrell JE, Young WL, eds. Cottrell and Young’s Neuroanesthesia, 5th ed., Philadelphia (PA): Mosby Elsevier; 2010:343−89.

15. Sahin T, Arslan ZI, Akansel G, et al. Fluoroscopic comparison of ¸ cervical spine motion using LMA CTrach, C-MAC videolaryngoscope and Macintosh laryngoscope. Turk J Anaesthesiol Reanim. 2018;46:44−50.

16. Gomez-Rios MA, Sastre JA, Onrubia-Fuertes X, et al. Spanish Society of Anesthesiology, Reanimation and Pain Therapy (SEDAR), Spanish Society of Emergency and Emergency Medicine (SEMES) and Spanish Society of Otolaryngology, Head and Neck Surgery (SEORL-CCC) Guideline for difficult airway management. Part I. Rev Esp Anestesiol Reanim (Engl Ed). 2024;71:171−206.

17. Gomez-Rios MA, Sastre JA, Onrubia-Fuertes X, et al. Spanish Society of Anesthesiology, Reanimation and Pain Therapy (SEDAR), Spanish Society of Emergency and Emergency Medicine (SEMES) and Spanish Society of Otolaryngology, Head and Neck Surgery (SEORL-CCC) Guideline for difficult airway management. Part II. Rev Esp Anestesiol Reanim (Engl Ed). 2024;71:207−47.

18. Gomez-Rios MA, Van Zundert AAJ, McNarry AF, et al. Guidelines on strategies for the universal implementation of videolaryngoscopy. Eur J Anaesthesiol. 2025;42:872−88.

19. Gomez-Rios MA, Michalek P, Gaszynski T, Van Zundert AAJ. Human Factors in Airway Management: Designing Systems for Safer, Team-Based Care. J Clin Med. 2025;14:8850.


Submitted date:
04/10/2026

Accepted date:
10/05/2026

6b05a968a953953af3332b4b rba Articles
Links & Downloads

Braz J Anesthesiol

Share this page
Page Sections