Brazilian Journal of Anesthesiology
https://app.periodikos.com.br/journal/rba/article/6b05adbba953953dac0315db
Brazilian Journal of Anesthesiology
Original Investigation

GlideRite® rigid stylet vs Flex-it® articulated stylet for intubation with videolaryngoscopy in patients with semi-rigid cervical collar: a randomized trial

Mandril rígido GlideRite® vs. mandril articulado Flex-it® para intubação com videolaringoscopia em pacientes com colar cervical semirrígido: um ensaio randomizado

John Viet Nguyen, Eric Zhu, Said Dababneh, Pierre Drolet, Marie-Ève Bélanger, Rami Issa, Valerie Zaphiratos, Nadia Godin, Jean S. Bussières, Mihai Georgescu, Issam Tanoubi

Downloads: 0
Views: 2

Abstract

Background

Compared with the GlideRite® rigid stylet used with the GlideScope® hyperangulated blade, the Flex-it® stylet permits dynamic orientation of the tracheal tube toward the glottis. This randomized trial compared GlideRite and Flex-it stylets regarding GlideScope intubation duration in patients wearing a semi-rigid cervical collar, simulating conditions of cervical instability.

Methods

Eighty adult patients undergoing elective surgery were randomized to tracheal intubation using the GlideScope with either the GlideRite or the Flex-it stylet. A semi-rigid cervical collar was applied following anesthesia induction. The primary endpoint was intubation duration in seconds. For our modified Intention-To-Treat (mITT) analysis, failed intubations were assigned the maximum duration of 180 seconds. Secondary outcomes included tracheal tube handling duration, intubation failure, Intubation Difficulty Scale, and ease of stylet removal.

Results

Seventy-five patients were included in the mITT analysis (n = 38 for Flex-it, 37 for GlideRite). Intubation duration was longer when using Flex-it compared with GlideRite (median [IQR]: 88 [65‒180] vs. 49 [39‒61] s) with a median difference of 37 s (95% CI: 22 to 64; p < 0.0001). Tube handling duration was longer with Flex-it (median [IQR]: 48 [33‒66] vs. 34 [25‒39] s; p = 0.007). Failure rate was significantly higher with Flex-it (15/38, 39.5%) than with GlideRite (2/37, 5.4%; p < 0.001). Intubation Difficulty Scale score was higher for Flex-it (median [IQR]: 6 [5‒7] vs. 2 [2‒5]; p < 0.001).

Conclusion

In elective patients with simulated cervical instability, videolaryngoscopy with the Flex-it stylet resulted in longer intubation, greater difficulty, and higher failure rate compared with the GlideRite stylet.

Keywords

Airway management; Immobilization; Intubation, intratracheal; Laryngoscopes; Laryngoscopy; Randomized controlled trial

Resumo

Introdução

Em comparação com o mandril rígido GlideRite® usado com a lâmina hiperangulada GlideScope®, o mandril Flex-it® permite a orientação dinâmica do tubo traqueal em direção à glote. Este ensaio randomizado comparou os mandris GlideRite e Flex-it quanto à duração da intubação com GlideScope em pacientes usando colar cervical semirrígido, simulando condições de instabilidade cervical.

Métodos

Oitenta pacientes adultos submetidos à cirurgia eletiva foram randomizados para intubação traqueal utilizando o GlideScope com o mandril GlideRite ou o mandril Flex-it. Um colar cervical semirrígido foi aplicado após a indução da anestesia. O desfecho primário foi a duração da intubação em segundos. Para nossa análise de Intenção de Tratar modificada (mITT), às intubações malsucedidas foi atribuída a duração máxima de 180 segundos. Os desfechos secundários incluíram duração do manejo do tubo traqueal, falha na intubação, Escala de Dificuldade de Intubação e facilidade de remoção do mandril.

Resultados

Setenta e cinco pacientes foram incluídos na análise mITT (n = 38 para Flex-it, 37 para GlideRite). A duração da intubação foi maior com o uso do Flex-it em comparação ao GlideRite (mediana [IIQ]: 88 [65–180] vs. 49 [39–61] s), com uma diferença mediana de 37 s (IC 95%: 22 a 64; p < 0,0001). A duração do manejo do tubo foi maior com o Flex-it (mediana [IIQ]: 48 [33–66] vs. 34 [25–39] s; p = 0,007). A taxa de falha foi significativamente maior com o Flex-it (15/38, 39,5%) do que com o GlideRite (2/37, 5,4%; p < 0,001). O escore na Escala de Dificuldade de Intubação foi maior para o Flex-it (mediana [IIQ]: 6 [5–7] vs. 2 [2–5]; p < 0,001).

Conclusão

Em pacientes eletivos com instabilidade cervical simulada, a videolaringoscopia com o mandril Flex-it resultou em maior tempo de intubação, maior dificuldade e maior taxa de falha em comparação com o mandril GlideRite.

Palavras-chave

Manejo de vias aéreas; Imobilização; Intubação intratraqueal; Laringoscópios; Laringoscopia; Ensaio clínico randomizado

Referencias

1. van Zundert A, Maassen R, Lee R, et al. A Macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways. Anesth Analg. 2009;109:825−31.

2. Turkstra TP, Harle CC, Armstrong KP, et al. The GlideScopespecific rigid stylet and standard malleable stylet are equally effective for GlideScope use. Can J Anaesth. 2007;54:891−6.

3. Xue FS, Liao X, Liu JH, Yuan YJ, Wang Q. Performance of the GlideRite® Rigid Stylet and malleable stylet for tracheal intubation by novices using the GlideScope® videolaryngoscope. Can J Anaesth. 2011;58:660−1.

4. Schulz KF, Altman DG, Moher D. CONSORT Group. CONSORT 2010 statement: updated guidelines for reporting parallel group randomised trials. BMJ. 2010;340:c332.

5. Pius J, Noppens RR. Learning curve and performance in simulated difficult airway for the novel C-MAC video-stylet and CMAC Macintosh video laryngoscope: a prospective randomized manikin trial. PLoS One. 2020;15:e0242154.

6. Adnet F, Borron SW, Racine SX, et al. The intubation difficulty scale (IDS): proposal and evaluation of a new score characterizing the complexity of tracheal intubation. Anesthesiology. 1997;87:1290−7.

7. Vijayakumar V. Intubation Difficulty Scale Score and Videolaryngoscopes. J Neurosurg Anesthesiol. 2017;29:70−1.

8. McElwain J, Simpkin A, Newell J, Laffey JG. Determination of the utility of the Intubation Difficulty Scale for use with indirect laryngoscopes. Anaesthesia. 2011;66:1127−33.

9. Turkstra TP, Jones PM, Ower KM, Gros ML. The Flex-It stylet is less effective than a malleable stylet for orotracheal intubation using the GlideScope. Anesth Analg. 2009;109: 1856−9.

10. Hozo SP, Djulbegovic B, Hozo I. Estimating the mean and variance from the median, range, and the size of a sample. BMC Med Res Methodol. 2005;5:13.

11. Rosner B. Fundamentals of biostatistics. 7th ed. Boston: Brooks/ Cole; 2011.

12. Bak JW, Noh Y, Kim J, et al. Comparison between GlideRite rigid stylet and Parker Flex-It stylet to facilitate GlideScope intubation in simulated difficult intubation: a randomized controlled study. Anesth Pain Med (Seoul). 2022;17:104−11.

13. Sheta SA, Abdelhalim AA, ElZoughari IA, AlZahrani TA, Al-Saeed AH. Parker Flex-It stylet is as effective as GlideRite rigid stylet for orotracheal intubation by Glidescope. Saudi Med J. 2015;36:1446−52.

14. Reus E, Grundmann U, Liening K, Wrobel M. Parker Flex-It intubation stylet versus a 90-degree curved stylet during intubation with the McGrath videolaryngoscope performed by novices: a manikin study with 5 airway scenarios. J Clin Anesth. 2013;25:624−8.

15. Ueshima H, Terao K, Kitamura A. Successful intubation in a patient with limited oral opening by using a combination of the Parker Flex-IT stylet and McGRATH MAC laryngoscopy. Masui. 2015;64:1056−8. Japanese.

16. Arai T, Yamamoto Y, Kikuchi A, Okuda Y. Use of a new videolaryngoscope (McGRATH X-blade) in patients with difficult airways. Masui. 2015;64:1048−51. Japanese.

17. McElwain J, Malik MA, Harte BH, Flynn NH, Laffey JG. Determination of the optimal stylet strategy for the C-MAC videolaryngoscope. Anaesthesia. 2010;65:369−78.

18. Zhang J, Tan LZ, Toh H, et al. Comparing the first-attempt tracheal intubation success of the hyperangulated McGrath X-blade vs the Macintosh-type CMAC videolaryngoscope in patients with cervical immobilization: a two-centre randomized controlled trial. J Clin Monit Comput. 2022;36:1139−45.

19. Griesdale DE, Liu D, McKinney J, Choi PT. GlideScope video-laryngoscopy versus direct laryngoscopy for endotracheal intubation: a systematic review and meta-analysis. Can J Anaesth. 2012;59:41−52.


Submitted date:
10/01/2026

Accepted date:
23/08/2026

6b05adbba953953dac0315db rba Articles
Links & Downloads

Braz J Anesthesiol

Share this page
Page Sections