Este trabalho tem como objetivo avaliar a degradação térmica e fotooxidativa do terpolÃmero poli(acrilonitrilabutadieno- estireno), ABS, utilizado em componentes internos de automóveis. Corpos-de-prova de ABS moldados por injeção foram submetidos ao envelhecimento térmico, segundo a norma ASTM D794, e ao envelhecimento fotooxidativo segundo as normas ASTM G24 e G53. As amostras envelhecidas foram submetidas à s análises dinâmico-mecânica e microscópicas por microscopia de força atômica, no modo não contato. Os resultados mostraram que as transições, tanto da fase vÃtrea quanto da fase elastomérica na superfÃcie do ABS, são afetadas pela degradação. As áreas dos picos das curvas de módulo de perda em função da temperatura relativos à s transições vÃtreas do ABS foram correlacionadas ao alongamento na ruptura, em função do tempo e tipo de envelhecimento. As propriedades mecânicas são influenciadas de forma mais acentuada pela extensão da degradação da matriz. O método de envelhecimento ASTM G24 mostrou-se mais agressivo que o G53, seja para a fase BR ou para a fase SAN. As imagens microscópicas mostraram que os diferentes envelhecimentos provocaram diferentes variações na rugosidade das superfÃcies. Amostras fotooxidadas, com perda de alongamento maior que 50%, foram reprocessadas e mostraram uma recuperação superior a 90% nessa propriedade.
Palavras-chave
ABS, degradação, propriedades mecânicas, reciclagem
Abstract
The aim of this work is the evaluation of thermal and photo-oxidative degradation of the terpolymer acrylonitrile- butadiene-styrene, ABS, used in internal automotive components. Injection molded specimens were aged according to ASTM D794, ASTM G24 and ASTM G53 standards. The aged test specimens were studied by means of dynamic mechanical analysis and non-contact atomic force microscopy. The results revealed that the transitions of the glass and rubber phases were affected by degradation. The area under the linear loss modulus-temperature curves was related to tensile properties as a function of the aging time and standard test method. The degradation of the matrix had a higher influence on the mechanical properties. Both PB and SAN phases were more affected when the ASTM G24 standard test method was used. Microscopy images showed that distinct ageing methods cause different changes on the surface roughness. The results showed that an ABS that had lost 50% of rupture elongation has this property almost regenerated (90%) after being reprocessed.
Keywords
ABS, degradation, mechanical properties, recycling
References
1. Pospisil, J.; Horák, Z.; Krulis, Z.; Nespurek, S.; Kuroda, S. Polym. Deg. Stab., 65, p.405, 1999.
2. Adeniyi, J. B.; Kolawole, E.G. Eur. Polym. J., 20, p.43, 1984.
3. Jouan, X.; Gardette, J. L. Polym. Deg. Stab., 36, p.91, 1991.
4. Gardette, J. L.; Mailhot, B.; Lemaire, J. Polym. Deg. Stab., 48, p.457, 1995.
5. Adeniyi, J. B. Eur. Polym. J. – 20, p.291, 1984.
6. Sanchez, E. M. S.; Ferreira, M. M. C.; Felisberti, M. I. PolÃmeros: Ciência e Tecnologia, Out/Dez, p.116, 1999.
7. Wyzgoski, M. G. J. Appl. Polym. Sci., 25, p.1443, 1980.
8. Fay, J. J.; Thomas, D. A.; Sperling, L. H. J. Appl. Polym. Sci., p.1617, 1991.