Manual Therapy, Posturology & Rehabilitation Journal
https://app.periodikos.com.br/journal/mtprehab/article/doi/10.17784/mtprehabjournal.2017.15.458
Manual Therapy, Posturology & Rehabilitation Journal
Research Article

Varied EMG responses of the quadriceps muscle during a Wingate anaerobic test

Okano, Alexandre Hideki; Moraes, Antonio Carlos de; Bankoff, Antonia Dalla Pria; Cyrino, Edilson Serpeloni; Simões, Herbert Gustavo; Pezarat-Correia, Pedro; Barbieri, João Francisco; Teodoro, Cássia Lopes; Gáspari, Arthur Fernandes

Downloads: 0
Views: 1171

Abstract

Introduction: The Wingate Test (WAnT) has been used to evaluate anaerobic performance in cycle ergometer. Objective: The purpose of the present study was to analyze the EMG response of the superficial quadriceps femoris muscles during the Wingate anaerobic test (WAnT). In addition, we investigated the influence of these muscles in performance and fatigue during the WAnT. Methods: For this purpose eight male cyclists performed a 30-s WAnT. Electromyographic amplitude (RMS) and median power frequency (MPF) data of the vastus lateralis (VL), vastus medialis (VM), and rectus femoris (RF) muscles, performance index (mean power, MP) and rate of fatigue (fatigue index, FI) were recorded during the test; and compared along six time points. The correlation between EMG data and performance parameters were made. Results: No significant differences were found in maximal EMG amplitude for all the muscles. TheMPF of the VL and VM muscles decreased throughout the test (12% and 13%, respectively), however, the decline for the RF was twice greater (25%). Correlation among MP and EMG amplitude was observed only for VL (r=0.83; P<0.01). There was significant correlation between the FI and the MPF decrease in the RF muscle only (r=0.78; P<0.05). Conclusion: During the WAnT, MPF decrease of RF muscle was significantly larger when compared to the VL and VM. The VL muscle electrical activity was positively correlated with MP, suggesting that VL is an accurate predictor of the performance in the WAnT. The MPF decrease of the RF muscle was positively correlated to the FI. These results may be explained by differences in the fiber type composition, biomechanics and architecture properties of these muscles.

Keywords

Wingate anaerobic test, Electromyography, Quadriceps Muscle, Fatigue, Neuromuscular.

References

1. Bar-Or O. The Wingate anaerobic test. An update on methodology, reliability and validity. Sports medicine. 1987;4(6):381-94.

2. Bulbulian R, Jeong JW, Murphy M. Comparison of anaerobic components of the Wingate and Critical Power tests in males and females. Medicine and science in sports and exercise. 1996;28(10):1336-41.

3. Micklewright D, Alkhatib A, Beneke R. Mechanically versus electromagnetically braked cycle ergometer: performance and energy cost of the Wingate Anaerobic Test. European journal of applied physiology. 2006;96(6):748-51.

4. Inbar O, Bar-Or O, Skinner J. The Wingate anaerobic test: development, characteristics, and application. Champaign (IL): Human Kinetics. 1996.

5. Vandewalle H, Peres G, Monod H. Standard anaerobic exercise tests. Sports medicine. 1987;4(4):268-89.

6. Beneke R, Pollmann C, Bleif I, Leithauser RM, Hutler M. How anaerobic is the Wingate Anaerobic Test for humans? European journal of applied physiology. 2002;87(4-5):388-92.

7. Bogdanis GC, Nevill ME, Boobis LH, Lakomy HK, Nevill AM. Recovery of power output and muscle metabolites following 30 s of maximal sprint cycling in man. The Journal of physiology. 1995;482 (Pt 2):467-80.

8. Vincent S, Berthon P, Zouhal H, Moussa E, Catheline M, Bentue-Ferrer D, et al. Plasma glucose, insulin and catecholamine responses to a Wingate test in physically active women and men. European journal of applied physiology. 2004;91(1):15-21.

9. Weinstein Y, Bediz C, Dotan R, Falk B. Reliability of peak-lactate, heart rate, and plasma volume following the Wingate test. Medicine and science in sports and exercise. 1998;30(9):1456-60.

10. Lovell D, Kerr A, Wiegand A, Solomon C, Harvey L, McLellan C. The contribution of energy systems during the upper body Wingate anaerobic test. Applied physiology, nutrition, and metabolism = Physiologie appliquee, nutrition et metabolisme. 2013;38(2):216-9.

11. Bell DG, Jacobs I, Ellerington K. Effect of caffeine and ephedrine ingestion on anaerobic exercise performance. Medicine and science in sports and exercise. 2001;33(8):1399-403.

12. Casey A, Constantin-Teodosiu D, Howell S, Hultman E, Greenhaff PL. Creatine ingestion favorably affects performance and muscle metabolism during maximal exercise in humans. The American journal of physiology. 1996;271(1 Pt 1):E31-7.

13. Collomp K, Le Panse B, Portier H, Lecoq AM, Jaffre C, Beaupied H, et al. Effects of acute salbutamol intake during a Wingate test. International journal of sports medicine. 2005;26(7):513-7.

14. Engels HJ, Kolokouri I, Cieslak TJ, 2nd, Wirth JC. Effects of ginseng supplementation on supramaximal exercise performance and short-term recovery. Journal of strength and conditioning research. 2001;15(3):290-5

15. Greer F, McLean C, Graham TE. Caffeine, performance, and metabolism during repeated Wingate exercise tests. Journal of applied physiology. 1998;85(4):1502-8.

16. Kocak S, Karli U. Effects of high dose oral creatine supplementation on anaerobic capacity of elite wrestlers. The Journal of sports medicine and physical fitness. 2003;43(4):488-92.

17. Kreider RB, Melton C, Greenwood M, Rasmussen C, Lundberg J, Earnest C, et al. Effects of oral D-ribose supplementation on anaerobic capacity and selected metabolic markers in healthy males. International journal of sport nutrition and exercise metabolism. 2003;13(1):76-86.

18. Fujii N, Tsuchiya S, Tsuji B, Watanabe K, Sasaki Y, Nishiyasu T. Effect of voluntary hypocapnic hyperventilation on the metabolic response during Wingate anaerobic test. European journal of applied physiology. 2015;115(9):1967-74.

19. Jorge M, Hull ML. Analysis of EMG measurements during bicycle pedalling. Journal of biomechanics. 1986;19(9):683-94.

20. Driss T, Vandewalle H. The measurement of maximal (anaerobic) power output on a cycle ergometer: a critical review. BioMed research international. 2013;2013:589361.

21. Ebenbichler G, Kollmitzer J, Quittan M, Uhl F, Kirtley C, Fialka V. EMG fatigue patterns accompanying isometric fatiguing knee-extensions are different in mono- and bi-articular muscles. Electroencephalography and clinical neurophysiology. 1998;109(3):256-62.

22. Kouzaki M, Shinohara M, Fukunaga T. Non-uniform mechanical activity of quadriceps muscle during fatigue by repeated maximal voluntary contraction in humans. European journal of applied physiology and occupational physiology. 1999;80(1):9-15.

23. Vaz MA, Zhang YT, Herzog W, Guimaraes AC, MacIntosh BR. The behavior of rectus femoris and vastus lateralis during fatigue and recovery: an electromyographic and vibromyographic study. Electromyography and clinical neurophysiology. 1996;36(4):221-30.

24. Wretling ML, Henriksson-Larsen K, Gerdle B. Inter-relationship between muscle morphology, mechanical output and electromyographic activity during fatiguing dynamic knee-extensions in untrained females. European journal of applied physiology and occupational physiology. 1997;76(6):483-90.

25. Akima H, Saito A. Activation of quadriceps femoris including vastus intermedius during fatiguing dynamic knee extensions. European journal of applied physiology. 2013;113(11):2829-40.

26. Hunter AM, St Clair Gibson A, Lambert MI, Nobbs L, Noakes TD. Effects of supramaximal exercise on the electromyographic signal. British journal of sports medicine. 2003;37(4):296-9.

27. Vandewalle H, Maton B, Le Bozec S, Guerenbourg G. An electromyographic study of an all-out exercise on a cycle ergometer. Archives internationales de physiologie, de biochimie et de biophysique. 1991;99(1):89-93.

28. Souissi H, Chtourou H, Chaouachi A, Chamari K, Souissi N, Amri M. Time-ofDay Effects on EMG Parameters During the Wingate Test in Boys. Journal of sports science & medicine. 2012;11(3):380-6.

29. Okano AH, Altimari LR, Moraes AC, Teixeira O, Ravagnani FC, Coelho CF, et al. Comparison between individual anaerobic threshold and ventilatory threshold determined in cyclists. Medicine & Science in Sports & Exercise. 2003;35(5):S118.

30. Hermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. Journal of electromyography and kinesiology: official journal of the International Society of Electrophysiological Kinesiology. 2000;10(5):36174.

31. Kinugasa R, Hayashi S, Iino N, Tamura M, Oouchi T, HORI A. Recruitment pattern of quadriceps femoris muscles during repetitive knee extension exercise by muscle functional MRI. Journal of Physical Exercise and Sports Science, Tokyo. 2002;8:1-6.

32. Tesch PA, Dudley GA, Duvoisin MR, Hather BM, Harris RT. Force and EMG signal patterns during repeated bouts of concentric or eccentric muscle actions. Acta physiologica Scandinavica. 1990;138(3):263-71.

33. Wickiewicz TL, Roy RR, Powell PL, Edgerton VR. Muscle architecture of the human lower limb. Clinical orthopaedics and related research. 1983(179):275-83.

34. Housh TJ, deVries HA, Johnson GO, Housh DJ, Evans SA, Stout JR, et al. Electromyographic fatigue thresholds of the superficial muscles of the quadriceps femoris. European journal of applied physiology and occupational physiology. 1995;71(2-3):131-6.

35. Johnson MA, Sideri G, Weightman D, Appleton D. A comparison of fibre size, fibre type constitution and spatial fibre type distribution in normal human muscle and in muscle from cases of spinal muscular atrophy and from other neuromuscular disorders. Journal of the neurological sciences. 1973;20(4):345-61.

36. Aagaard P, Andersen JL, Dyhre-Poulsen P, Leffers AM, Wagner A, Magnusson SP, et al. A mechanism for increased contractile strength of human pennate muscle in response to strength training: changes in muscle architecture. The Journal of physiology. 2001;534(Pt. 2):613-23.

37. Bressel E. Biomechanical Basis of Human Movement. Medicine & Science in Sports & Exercise. 2003;35(10):1795.

38. Edgerton VR, Smith JL, Simpson DR. Muscle fibre type populations of human leg muscles. The Histochemical journal. 1975;7(3):259-66.

39. Watanabe K, Akima H. Neuromuscular activation of vastus intermedius muscle during fatiguing exercise. Journal of electromyography and kinesiology: official journal of the International Society of Electrophysiological Kinesiology. 2010;20(4):661-6.

40. Grabiner MD, Koh TJ, Miller GF. Fatigue rates of vastus medialis oblique and vastus lateralis during static and dynamic knee extension. Journal of orthopaedic research: official publication of the Orthopaedic Research Society. 1991;9(3):391-7.

41. Basmajian JV, De Luca C. Muscles alive. Muscles alive: their functions revealed by electromyography. 1985;278:126.

42. McCool P, Fraser GD, Chan AD, Petropoulakis L, Soraghan JJ. Identification of contaminant type in surface electromyography (EMG) signals. IEEE transactions on neural systems and rehabilitation engineering: a publication of the IEEE Engineering in Medicine and Biology Society. 2014;22(4):774-83.

43. Hannukainen JC, Nuutila P, Kaprio J, Heinonen OJ, Kujala UM, Janatuinen T, et al. Relationship between local perfusion and FFA uptake in human skeletal muscle-no effect of increased physical activity and aerobic fitness. Journal of applied physiology. 2006;101(5):1303-11.

5aa01d520e88251c4077d859 mtprehab Articles
Links & Downloads

Man. Ther., Posturology Rehabil. J.

Share this page
Page Sections