Is the preoperative leg axis similar in radiographic and computer measurements in frontal deformities?

¿El eje de la pierna preoperatoria es similar en las mediciones radiográficas y computacionales en las deformidades frontales?

Daniel Hernández-Vaquero, Alfonso Noriega-Fernández, Sergio Roncero-González

Downloads: 0
Views: 20

Abstract

Introduction: A prerequisite for ensuring a good clinical and functional outcome in total knee arthroplasty is knowing the preoperative leg alignment. This alignment is obtained using a long radiograph including the hip and knee, or a computer algorithm derived from palpation of landmarks and mapping of bone structures. It has been recommended to omit the preoperative radiograph if technology-assisted systems are to be used, but doubts exist regarding the similarity between both measurements, especially in frontal varus or valgus deformities.
Material and methods: The preoperative leg alignment was analyzed in 123 patients scheduled for total knee arthroplasty. Thirty-eight had a preoperative valgus axis radiographically, and 85 had a varus axis. A computer program was used to perform the radiographic measurement of the mechanical axis of the leg, and at the start of the procedure, this same measurement was verified with a technology-assisted navigation system (TAS).
Results: In the valgus group, the mean preoperative radiographic axis was 169.1º (SD 5.06), while the axis measured using the TAS was 171.9º (SD 3.96) (p=0.009). In the varus group, the mean radiographic axis was 191.9º (SD 5.86), and the axis measured using the TAS was 189.7º (SD 4.84) (p=0.008). The Pearson correlation coefficient comparing both measurements was 0.650 in the varus group and 0.237 in the valgus group (p=0.151).
Conclusions: The discrepancy between limb axis measurements obtained radiographically and those obtained with technological aids does not preclude the use of radiography in the preoperative evaluation of total knee arthroplasties.

Keywords

Leg axis; Computer measurement; Radiographic measurements; Technological-assisted systems; Navigation; Total knee arthroplasty

Resumen

Introducción: Una condición imprescindible para asegurar un buen resultado clínico y funcional de la artroplastia total de rodilla es conocer la alineación previa de la pierna. Para obtener esta alineación se utiliza la radiografía larga incluyendo cadera y rodilla o un algoritmo informático conseguido a partir de palpación de referencias y mapeo de estructuras óseas. Se ha recomendado obviar la radiografía previa si se va a utilizar sistemas asistidos con tecnología, pero existen dudas en cuanto a la similitud entre ambas mediciones, sobre todo en deformidades frontales en varo o valgo
Material y métodos: Se ha analizado la alineación preoperatoria de la pierna en 123 pacientes que iban a ser intervenidos para implantar una artroplastia total de rodilla. Treinta y ocho tenían radiográficamente un eje preoperatorio en valgo y 85 en varo. Se utilizó un programa informático para realizar la medición radiográfica del eje mecánico de la pierna y al iniciar el procedimiento se comprobó esta misma medición con un sistema de navegación con ayuda tecnológica (TAS).
Resultados: En el grupo de valgo el eje preoperatorio radiográfico medio fue de 169.1º (SD 5.06) y el que se mostró mediante el TAS fue de 171.9º (SD 3.96) (p=0.009). En el grupo de varo la media radiográfica fue de 191.9º (SD 5.86) y el mostrado por la TAS de 189.7º (SD 4.84) (p=0.008). El coeficiente de correlación de Pearson comparando ambas mediciones fue de 0.650 en el grupo de varos y 0.237 en el de valgos (p=0.151).
Conclusiones: La discordancia entre la medición del eje de la extremidad obtenida radiográficamente o con sistemas de ayuda tecnológica no permite obviar la realización de una radiografía en el estudio preoperatorio de las artroplastias totales de rodilla.

Palabras clave

Eje de la pierna; Mediciones con computadora; Mediciones radiográficas; Sistemas de asistencia tecnológica; Navegación; Artroplastia total de rodilla

References

1.Zheng Y, Li Y, Yuan Z, Geng X, Tian H. Comparison of the accuracy and efficacy of different assistive techniques in primary total knee arthroplasty: A network meta-analysis. J Exp Orthop. 2024;11(4):e70098. doi: 10.1002/jeo2.70098.
2.Hernández-Vaquero D, Suarez-Vazquez A, Sandoval-Garcia MA, Noriega-Fernandez A. Computer assistance increases precision of component placement in total knee arthroplasty with articular deformity. Clin Orthop Relat Res. 2010;468(5):1237-41. doi: 10.1007/s11999-009-1175-1.
3.Rodriguez-Merchan EC. Patient Satisfaction Following Primary Total Knee Arthroplasty: Contributing Factors. Arch Bone Jt Surg. 2021;9(4):379-86. doi: 10.22038/abjs.2020.46395.2274.
4.Ritter MA, Davis KE, Meding JB, Pierson JL, Berend ME, Malinzak RA. The effect of alignment and BMI on failure of total knee replacement. J Bone Joint Surg Am. 2011;93(17):1588-96. doi: 10.2106/JBJS.J.00772.
5.Fontalis A, Luyckx T, Vanspauwen T, Moreels R, Mancino F, Raj RD, ET AL. Strong Correlation Between Standing Long-Leg Radiographs and CT Scans in Measuring Coronal Knee Alignment. J Bone Joint Surg Am. 2024;106(15):1373-83. doi: 10.2106/JBJS.23.01092.
6.Theeuwen DMJ, Dorling IM, Most J, van Drumpt RAM, van der Weegen W, Welting TJM, et al. Patient-specific instrumentation improved clinical outcome and implant survival but is not superior compared to conventional total knee arthroplasty: Ten years follow-up of a multicenter double-blind randomized controlled trial. Knee Surg Sports Traumatol Arthrosc. 2025;33(4):1371-7. doi: 10.1002/ksa.12505.
7.Tian Y, Ahmed AG, Hiredesai AN, Huang LW, Patel AM, Ghomrawi HMK. The Cost-Effectiveness of Computer-Assisted Compared with Conventional Total Knee Arthroplasty: A Payer's Perspective. J Bone Joint Surg Am. 2024;106(18):1680-7. doi: 10.2106/JBJS.23.00555.
8.McAuliffe M, Darwish I, Anderson J, Nicholls A, Corfield S, Harries D, et al. Association of Technology Usage and Decreased Revision TKA Rates for Low-Volume Surgeons Using an Optimal Prosthesis Combination: An Analysis of 53,264 Primary TKAs. J Bone Joint Surg Am. 2024;106(22):2063-72. doi: 10.2106/JBJS.24.00539.
9.Russell SP, Keyes S, Grobler G, Harty JA. Navigated versus conventionally instrumented total knee arthroplasty techniques: No difference in functional alignment or balance. Knee Surg Sports Traumatol Arthrosc. 2025;33(5):1763-72. doi: 10.1002/ksa.12557.
10.Peng Y, Ding R, Li M, Wang G, Zhong Z, Wei L, et al. Preoperative evaluation of femoral and tibial sagittal alignment in robotic-assisted and conventional total knee arthroplasty and consequences for practice. Int Orthop. 2024;48(8):2047-54. doi: 10.1007/s00264-024-06229-x.
11.Dexel J, Kirschner S, Günther KP, Lützner J. Agreement between radiological and computer navigation measurement of lower limb alignment. Knee Surg Sports Traumatol Arthrosc. 2014;22(11):2721-7. doi: 10.1007/s00167-013-2599-4.
12.Yaffe MA, Koo SS, Stulberg SD. Radiographic and navigation measurements of TKA limb alignment do not correlate. Clin Orthop Relat Res. 2008;466(11):2736-44. doi: 10.1007/s11999-008-0427-9.
13.Willcox NM, Clarke JV, Smith BR, Deakin AH, Deep K. A comparison of radiological and computer navigation measurements of lower limb coronal alignment before and after total knee replacement. J Bone Joint Surg Br. 2012;94(9):1234-40. doi: 10.1302/0301-620X.94B9.28250.
14.Maderbacher G, Schaumburger J, Baier C, Zeman F, Springorum HR, Dornia C, et al. Predicting knee rotation by the projection overlap of the proximal fibula and tibia in long-leg radiographs. Knee Surg Sports Traumatol Arthrosc. 2014;22(12):2982-8. doi: 10.1007/s00167-014-3327-4.
15.Brin YS, Livshetz I, Antoniou J, Greenberg-Dotan S, Zukor DJ. Precise landmarking in computer assisted total knee arthroplasty is critical to final alignment. J Orthop Res. 2010;28(10):1355-9. doi: 10.1002/jor.21139.
16.Schwarzkopf R, Meftah M, Marwin SE, Zabat MA, Muir JM, Lamb IR. The use of imageless navigation to quantify cutting error in total knee arthroplasty. Knee Surg Relat Res. 2021;33(1):43. doi: 10.1186/s43019-021-00125-z.
17.Luo TD, Martensson N, Howard JL, Stevens D, McIsaac KA, Lanting BA. Identifying Sources of Error in Computer-Navigated Total Knee Arthroplasty Using Sensitivity Analyses in Knee Models. J Arthroplasty. 2025;40(7S1):S354-S361. doi: 10.1016/j.arth.2025.02.061.


Submitted date:
07/15/2025

Reviewed date:
11/26/2025

Accepted date:
12/13/2025

Publication date:
12/16/2025